Adapters
adapters-1
Male Adapter H x MPT
(4) This Adapter allows for a transition from a Female threaded pipe or fitting to a System XFR pipe or fitting.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Female Adapter H x FPT
(4) This Adapter allows for a transition from a Male threaded pipe or fitting to a System XFR pipe or fitting.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Pipe Trap Adapter H x Slip Joint
(2) This hub ended Adapter is installed under a bathroom sink, allowing for a transition from a tubular sink drain tail piece to a System XFR P-Trap.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
90º Pipe Trap Adapter H x Slip Joint
Create a water tight seal at a 90 degree angle through a Slip Joint connection at the end of this Adapter. Often used in a pedestal sink installation to allow for a trasition from a sink drain tail pipe.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Tail Piece Adapter Sp x Slip Joint
(2) The adapter allows for an easy connection between spigot sink outlets and our System XFR piping system.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Plastic MJ Spigot MJ Sp x H
(3) Easily transforms your M-J Cast Iron Pipe to a PVC System XFR piping system.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Copper to DWV Adapter H x SJ
(2) Create a water tight seal when transitioning from Copper to System XFR pipe through a Slip Joint connection at the end of this Adapter.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation