P-Traps
p-traps
P-Trap Solvent Weld H x H
(4) Made for connections beneath a floor or roof drain to a tall piece using pipe and adapters.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
P-Trap Solvent Weld with Cleanout H x H
(2) Made for a connection to a vertical strainer tail pipe under a sink, the p-trap with Cleanout provides a horizontal transition to the DWV piping system while traping water in the lower half of the p-trap u-bend for preventing the release of sewer gas into the environment through the sink drain. Access for cleaning is provided by a cleanout plug with a reusable watertight gasket.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
P-Trap Union Connection H x H
(2) Installed under a bathroom or kitchen sink to prevent sewer gas from entering a building, the U-Bend is connected to the sink tail piece using an adapter sized to match the tail pipe of a System XFR system. The 90 degree portion is screwed to the U-Bend and directed towards the rest of the drainage line.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
Trap Union Connection with Cleanout H x H
Made for a connection to a vertical strainer tail pipe under a sink, the p-trap with union connection with Cleanout provides a horizontal transition to the DWV piping system while traping water in the lower half of the p-trap u-bend for preventing the release of sewer gas into the environment through the sink drain. A union connection to the u-bend and a cleanout plug with a reusable watertight gasket allow for cleaning of the p-trap.- When tested to the CAN/ULC S102.2 Standard, System XFR achieved a Flame Spread Rating of not greater than 25 and a Smoke Developed Classification of not greater than 50
- Meets National and Provincial Building Codes for high buildings, air plenums, noncombustible construction and penetrating a rate fire separation
- High impact strength in cold temperatures, exceeding CSA requirements
- Improved flow rates
- Lower thermal conductivity can reduce or eliminate the need for insulation
P-Trap Primer Tee H x H x FPT
(2) Prevents sewer gases from entering and moving within a building’s plumbing system. As water is exposed to the air, it is subject to evaporation over time in irregularly used floor drains; this leads to the release of sewer gas into the environment. The P-Trap Primer Connection Tee will mitigate this issue by adding Municipal water into the P-Trap to maintain a water seal that will protect a room or building from spreading sewer gases.- Easy to install
- Compact design; Lightweight
- Long-term performance
- National Pipe Thread (NPT) water line connection
- Fire Rated, Flame and Smoke CAN/ULC S102.2
- CSA approved, CSA B181.2